Variable area meter: 

Variable area ,variable flowrate ,pressure constant. Area is adjusted to keep the pressure constant and this change is proportional to the flowrate.

Eg.rotameter,cylinder and piston type flowmeters.

Variable head meter:

Variable pressure, variable flowrate,area constant.flow is proportional to sqrt(∆p).

Eg.orifice meter, venturimeter